Use-cases of the Greenwood-Power sensors #1

Reliable earth fault direction detection in compensated networks

detection in compensated networks

One of the simplest use case for installing a non-conventional instrument transformer into a Ring-Main-Unit is to detect the direction of an earth fault on the power line.

Utility companies need fast and reliable information’s on which cable, “left” or “right” the earth fault appeared. If every station gives an information of direction, the fault could be detected fast between two stations.

Reliable earth fault direction detection in compensated networks
Existing systems are made for net structures with high earth fault currents in the range of kA. This makes it easy for most of the systems to give reliable information about the direction of an earth fault. Compensated networks, which use a petersson coil in the starpoint of the transformers are usually set to earth fault currents lower than 2A! In this case, many existing systems have failure rates >10%.

By using dedicated high accuracy sensors from GWP, the problem is solved!

In connection with an IED, which has the capability to detect this low earth fault currents, the direction could be detected with a much higher probability of up to 99%.
All current sensors and voltage sensors could be used for this use-case. The accuracy of the sensors should be equal or better than class 1 acc. IEC61869.

Would you like to find out more about our products?

Get our digital catalog now!

GWP Catalog

Download our catalog here!

Related posts

Switch condition monitoring and detection

Switch condition monitoring and detection

Use-cases of the Greenwood-Power sensors #3 Switch condition monitoring and detectionA simple and basic use case for sensors are the recognition of the switch state of load- switches and circuit breakers or the status of fuses. Utility companies have more and more...

read more
Voltage limit regulation

Voltage limit regulation

Use-cases of the Greenwood-Power sensors #2 Voltage limit regulation on medium and low voltage sideO ne of the most important use case is to give the utility an instrument to maintain the given voltage band of +/-10% on medium and low voltage distribution grids. Due...

read more
Announcement investment

Announcement investment

Announcement about investment eQventure & tecnet equityWe are very pleased that the associated companies eQventure and tecnet Equity are convinced of our vision and our performance and have therefore decided to invest in our company.The investment will drive...

read more